Manuals and Side Load Charts

    Here are the Side Load Chart, Head Room Chart, Trolley Radius Chart, and Operation Manual.

 

SUPER CLAMP OPERATION MANUAL PDF CLICK HERE

*SEE CHARTS BELOW FOR MOST UP TO DATE SPECIFICATIONS*

 

SUPERCLAMP WORKING LOAD LIMITS 

REDUCTION IN WORKING LOAD LIMITS WHEN SIDE LOADS APPLIED
ANGLE FROM VERTICAL 0° to 15° 15° to 30° 30° to 45°
REDUCTION FACTOR NIL 17% 34% 50%
MODELS WLL/lbs. WLL/lbs. WLL/lbs. WLL/lbs.
S2A, S2AX, S5A 6720 5578 4435 3360
S3 8960 7437 5914 4480
S3X, S3A, S6A 11200 9296 7392 5600
S4S 13440 11155 8870 6720
S4A, S11 22400 18592 14784 11200
S12, S14 33601 27889 22177 16801
S15, S16 44800 37184 29568 22400
S17, S18 56000 46480 36960 28000
S19, S20 67200 55776 44352 33600

 

The above working load limits and deviations have been established specifically for most "S" type clamps and only apply in overhead beam attachment, i.e. do not apply if clamps are to be used for lifting beams.  (The Universal SuperClamp™ "USC" has been specifically designed for this purpose.) The tables apply to our clamps only (selected models) and we strongly advise that stress calculations should be carried out (by the user's engineering department) for any/all support steel work. AC and BFC clamp models can be safely side loaded with no reduction in WLL from 0 to 15 degrees. 

SUPERCLAMP HEAD ROOM CHART

MODEL ADJUSTMENT MIN ADJUSTMENT MAX HEADROOM MIN HEADROOM MAX
S1 3 7.5 8.25 6.25
S2 3 7.5 8.5 7.5
S2A 3 7.5 9 8.5
S3 6 10 10.5 9.75
S3A 6 12 11.5 10.5
S3X 3 7.5 9.5 8.75
S4A 8 18 16 13.75
S4S 8 18 16 13.75
S5 3.5 12 11.75 8.75
S5A 3.5 12 12.25 9.25
S6 3.5 12 12.25 9.25
S6A 3.5 12 12.5 9.5
S7 3 7.5 8.5 7.5
S7A 3 7.5 8.5 7.5
S8 6 10 10.5 9.75
S8A 6 10 10.5 9.75
S11 3.5 12 13.5 11.5
S12 8 18 19.5 16.75
S14 16 24 22.25 19
S15 8 18 20.5 18.5
S16 16 24 22.5 19.25
S17 8 18 20.25 17
S18 16 24 22.75 19.75
S19 8 18 20.25 17
S20 16 24 22.75 20.25
BA1 2.5 8 9.75 8
BA2 3 8 9.75 8
BA3 3 8 9.75 8
B1 3 8 11 9.5
B2 4 12 14 12
B3 4 12 15 13
GBT1 3 8 11 9.5
GBT2 4 12 14 12
GBT3 4 12 15.75 13.75
GBT4 8 18 23 19.5
A1  - 8  - 9
A2  - 12  - 17
A3  - 12  - 19
PFC1 3 7.5 5.5 4.5
PFC2 3 7.5 5.5 4.5


 

 SUPERCLAMP TROLLEY RADIUS CHART

MINIMUM RADIUS FOR RUNWAY BEAM TROLLEYS
BA-Series 4.9 foot radius / 1.5 meter radius
B-Series 4.9 foot radius / 1.5 meter radius
A-Series 4.9 foot radius / 1.5 meter radius
GBT-1/2/3 4.9 foot radius / 1.5 meter radius
GBT-4/5 6.5 foot radius / 2.0 meter radius


WARNING: All Clamps must be correctly applied to the beam by a competent person and fully hand-tightened. If in doubt, contact the manufacturer for their recommendations!